期刊论文详细信息
Sustainability
Development of an Electrical Energy Consumption Model for Malaysian Households, Based on Techno-Socioeconomic Determinant Factors
Jorge Alfredo Ardila-Rey1  Hom Bahadur Rijal2  Sheikh Ahmad Zaki3  Boni Sena3  Fitri Yakub3  Farah Liana3  Nelidya Md Yusoff4  Mohamad Zaki Hassan4 
[1] Department of Electrical Engineering, Universidad Técnica Federico Santa María, Santiago de Chile 8940000, Chile;Faculty of Environmental Studies, Tokyo City University, Yokohama 224-8551, Japan;Malaysia-Japan International Institute of Technology, Universiti Teknologi Malaysia, Kuala Lumpur 54100, Malaysia;Razak Faculty of Technology and Informatics, Universiti Teknologi Malaysia, Kuala Lumpur 54100, Malaysia;
关键词: electrical energy consumption model;    artificial neural network;    socio-demographic;    house characteristics;    occupant behavior;    appliance characteristic;   
DOI  :  10.3390/su132313258
来源: DOAJ
【 摘 要 】

Energy-saving strategies are required to address the increasing global CO2 and electrical energy consumption problems. Therefore, the determinant factors of electrical energy consumption consist of socio-demographic changes, occupant behavior, house and appliance characteristics, or so-called techno-socioeconomic factors, which all need to be assessed. Statistics models, such as the artificial neural network (ANN), can investigate the relationship among those factors. However, the previous ANN model only used limited factors and was conducted in the developed countries of subtropical regions with different determinant factors than those in the developing countries of tropical regions. Furthermore, the previous studies did not investigate the various impacts of techno-socioeconomic factors concerning the performance of the ANN model in estimating monthly electrical energy consumption. The current study develops a model with a more-in depth architecture by examining the effect of additional factors such as socio-demographics, house characteristics, occupant behavior, and appliance characteristics that have not been investigated concerning the model performance. Thus, a questionnaire survey was conducted from November 2017 to January 2018 with 214 university students. The best combination factors in explaining the monthly electrical energy consumption were developed from occupant behavior, with 81% of the variance and a mean absolute percentage error (MAPE) of 20.6%, which can be classified as a reasonably accurate model. The current study’s findings could be used as additional information for occupants or for companies who want to install photovoltaic or wind energy systems.

【 授权许可】

Unknown   

  文献评价指标  