期刊论文详细信息
Indian Journal of Radiology and Imaging
Embolization of a large high-flow renal arteriovenous fistula using 035″ and 018″ detachable coils
Rajeev Suri1  Crysela M Smith1  Ghazwan M Kroma1  Jorge E Lopera1  Dinesh K Sundarakumar1 
[1] Department of Radiology, The University of Texas Health Science Center at San Antonio, 7703, Floyd Curl Drive, MC 7800, San Antonio, Texas 78229;
关键词: arteriovenous fistula;    embolization;    renal;    therapeutic;   
DOI  :  10.4103/0971-3026.116574
来源: DOAJ
【 摘 要 】

Transcatheter embolization of renal arteriovenous fistula (AVF) is a minimally invasive procedure that, in some occasions, can replace surgery and potentially save the kidney. The embolization techniques for the renal AVFs have evolved considerably with the availability of newer hardwares. Still, the risk of inadvertent migration of the embolization materials to the pulmonary circulation is a concern. This article describes a novel technique of coiling the feeding segmental artery to a large high-flow renal AVF using 035″ and 018″ detachable coils only, and briefly reviews the previously described strategies to safely embolize renal AVFs.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次