Budownictwo i Architektura | |
Research into steel-concrete bond in fire conditions | |
PawełOgrodnik1  ZojaBednarek2  | |
[1] Warsaw;The Main School of Fire Service; | |
关键词: bond test; concrete; steel; fire temperature; | |
DOI : 10.35784/bud-arch.2309 | |
来源: DOAJ |
【 摘 要 】
The article presents results from the research into fire temperature influence on steel-concrete bond and on the bond reduction for both in-fire and after-fire status. Bond tests and its results for materials St3S, 18G2 reinforced steel and C16/20, C40/50 concrete, have been described in the article both for in fire and after-fire conditions. All tests have shown a significant reduction of steel-concrete bond as a result of fire temperature. It was proven, that significant bond differences exist between in-fire and after-fire tests, what demonstrate that the bond is regained partially after the exposure.
【 授权许可】
Unknown