期刊论文详细信息
Clinical Case Reports
Coronary perforation during insertion of a long stent in a severely calcified lesion
Katsuhiko Takenaka1  Yoshinobu Murasato1  Kyohei Meno1  Takahiro Mori1 
[1] Department of Cardiology and Clinical Research Center National Hospital Organization Kyushu Medical Center Fukuoka Japan;
关键词: complication;    percutaneous coronary intervention;    stents;   
DOI  :  10.1002/ccr3.4217
来源: DOAJ
【 摘 要 】

Abstract We reported a case that the insertion of a 48‐mm‐long stent in a calcified coronary lesion after rotational atherectomy led to stent stacking and S‐shaped flection, resulting in longitudinal coronary perforation without stent inflation. Its flexibility and length pose a possible risk of deformation inside the vessel during stent insertion.