In Vitro Ion Release of Wires in Removable Orthodontic Appliances
Florian Heuser1  Andreas Jaensch2  Harald Andreas Färber2  Ludger Keilig3  Christoph Peter Bourauel3  Lena Wepner3  Lamia Singer3  Anna Weber3 
[1] Department of Prosthetic Dentistry, Preclinical Education and Materials Science, Dental School, Medical Faculty, University of Bonn, 53111 Bonn, Germany;Institute for Hygiene and Public Health, Medical Faculty, University of Bonn, 53127 Bonn, Germany;Oral Technology, Dental School, Medical Faculty, University of Bonn, 53111 Bonn, Germany;
关键词: removable appliance;    orthodontic wire;    corrosion;    cytotoxicity;   
DOI  :  10.3390/ma14123402
来源: DOAJ
【 摘 要 】

Various orthodontic wire compositions and configurations are present on the market for removable appliances; however, there have still been only few studies focusing on the effect of resin color and additives such as glitter on corrosion of metallic wires under different conditions. Thus, the aim of the study was to compare concentrations of released ions (aluminium, chromium, nickel) in a corrosive medium under three different conditions: non-loaded wires, loaded wires, and non-loaded wires treated with Kukis® cleaning tablets. Six different wires made of three types of steel alloy were embedded in PMMA resin leaving one centimetre of each wire emerging from the resin to come into contact with the corrosive medium. Glitter particles were added to half of the produced test specimens. For the unloaded test series, five specimens of each group were covered in a petri dish with 50 mL of corrosive medium (pH 2.3) following EN-ISO 10271 for seven days at 37 °C. The wires for the mechanically loaded test specimens overlapped the resin by 5 cm and were clamped into a time-switched electric drive for a defined period of time before the samples were taken after a testing time of 7 days. In the third group, unloaded test specimens were transferred from their petri dishes into the prepared Kukis® solution every 24 h before being stored in the corrosive medium. Inductively coupled plasma mass spectrometry (ICP-MS) was used to quantify the specific ions in the corrosive solution. Statistical analysis showed that the mechanical loading of all wires could significantly raise the diffusion of ions into the corrosive medium. The colour of the resin did not affect the concentration of the released ions. The Kukis® cleaning tabs could not lower the corrosion of the tested metals, as some of the wires were corroded even more using the brace cleanser. Glitter-containing test specimens showed significantly higher amounts of aluminium. Mechanical loading as well as the presence of glitter particles in the resin significantly affected ion concentrations.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次