期刊论文详细信息
Proceedings
Binary Zone Plate Infrared Spectrometer for Dissolved Gas Analysis in High Voltage Equipment
Pawel Glowacki1  Cyrus Shafai1 
[1] Department of Electrical and Computer Engineering, University of Manitoba, Winnipeg, MB, Canada;
关键词: binary zone plate;    IR spectroscopy;    dissolved gas analysis;    gas detection;    fourier optics;    spectrometer;   
DOI  :  10.3390/proceedings1040555
来源: DOAJ
【 摘 要 】

An IR spectrometer based on a Binary Zone Plate (BZP) is presented for dissolved gas analysis. The wavelength selective focal length of the BZP can effectively discriminate between wavelengths ranging from 800 nm to 8 μm, by adjusting the focus distance onto an aperture in the image plane from 19 mm to 200 mm. The aperture serves to pass focused radiation onto the detector. The BZP has a focal length of 50 mm for a design wavelength of 3 μm, with 400 zones. This design enables discrimination between all key fault gases present in oil impregnated high voltage equipment.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次