Development of Noise Measurements. Part 7. Coriolis Mass Flowmeter and its Errors | |
Bohdan STADNYK1  Pylyp SKOROPAD1  Halyna POL'OVA1  Svyatoslav YATSYSHYN1  | |
[1] Institute of Computer Technologies, Automation and Metrology, National University Lviv Polytechnic, Bandera str.12, Lviv, 79013, Ukraine; | |
关键词: Coriolis mass flowmeter; Instrumental error; Dynamic error; Differential thermocouple; Pt100 sensor.; | |
DOI : | |
来源: DOAJ |
【 摘 要 】
Coriolis mass flowmeter instrumental and dynamic errors are studied. They can be decreased by the thermocouple usage of R or S types instead of Pt100 sensors. The dynamic error analysis shows that it is able to improve the operation accuracy in the dynamic regime and eliminate the initial period of the flowmeter exploitation in the error compensation absence regime. In consequence of the instrumental error consideration the expediency of the differential thermocouples installation with the reduced performance dispersion, lowered by taking into account of local and extensive inhomogeneities as result of technological deviations of wire production.