Investigative and Clinical Urology | |
Evaluation of pain and catheter-related bladder discomfort relative to balloon volumes of indwelling urinary catheters: A prospective study | |
Ahmed S. Zugail1  Jacques Irani1  Ugo Pinar1  | |
[1] Department of Urology, Bicêtre Hospital, Le Kremlin-Bicêtre, France; | |
关键词: Clinical protocols; Pain management; Treatment outcome; Urinary bladder; Urinary catheters; | |
DOI : 10.4111/icu.2019.60.1.35 | |
来源: DOAJ |
【 摘 要 】
Purpose: To evaluate patients' tolerance to indwelling urinary catheters (IUCs) before and after reducing their balloon volumes. IUCs are a source of discomfort or pain. Materials and Methods: All consecutive patients hospitalized in our department with IUCs were included during the study period with some exclusion. Each patient was his/her own control before and two hours after reduction of the balloon volume (RBV) by half using two types of assessments, a visual analog scale for pain and a catheter-related bladder discomfort (CRBD) symptom questionnaire. Results: Forty-nine patients were included in our study that completed the assessments. The mean scores for pain before and after RBVs were 2.80 and 2.02, respectively. The difference was significant (p<0.05). The mean grades of the CRBD before and after RBVs were 1.02 and 0.75, respectively. The difference was significant (p<0.05). Conclusions: A 50% RBV has shown a significant amelioration in tolerating the catheter.
【 授权许可】
Unknown