环境与职业医学 | |
Determination of tin and its compounds in ambient PM2.5 by atomic fluorescence spectrometry after ultrasonic extraction with concentrated hydrochloric acid | |
Jinhua YUAN1  Liya WANG2  Lu KONG2  | |
[1] Nanjing Center for Disease Control and Prevention, Nanjing, Jiangsu 210009, China;School of Public Health, Southeast University, Nanjing, Jiangsu 210009, China; | |
关键词: fine particulate; quartz filter membrane; tin and its compounds; concentrated hydrochloric acid extraction; atomic fluorescence spectrometry; | |
DOI : 10.11836/JEOM21372 | |
来源: DOAJ |
【 摘 要 】
BackgroundTin and its compounds can cause serious harm to human respiratory system and nervous system, but there is no corresponding national standard method for the determination of tin in PM2.5. ObjectiveTo establish a method for the determination of tin and its compounds in PM2.5 by atomic fluorescence spectrometry (AFS) after ultrasonic extraction with concentrated hydrochloric acid. MethodsWe extracted a fixed volume of air at a constant speed through a sampler with preset cutting characteristics to trap PM2.5 in the ambient air on quartz filter membranes. By selecting extraction solvent, comparing extraction temperature and time, and adjusting the acidity of solution to be measured, the sample pretreatment process was optimized, and a method for the determination of tin and its compounds in PM2.5 by AFS was proposed, and its performance indexes such as linearity, detection limit, and lower limit of quantification were obtained. The accuracy and precision of the method were evaluated by the standard addition recovery test with blank quartz filter membranes, and the interference test was carried out by adding standard urban particulate samples. The proposed method and the method recommended by the “Handbook on Monitoring and Protection of Air Pollution (Haze) Effects on Population Health (2020)” (the Handbook) were applied to actual samples, and the results were compared. ResultsThis experiment used concentrated hydrochloric acid as the extraction solvent. The higher the reaction temperature and the longer the reaction time, the higher the recovery rate. Therefore, 70 ℃ water bath ultrasonic extraction for 3 h was selected. In terms of the proposed method, the linear range of detection was from 5.00 μg·L−1 to 50.00 μg·L−1, with a correlation coefficient ≥0.999 and a detection limit of 0.27 μg·L−1. When the quantitative detection of the lower limit was 0.90 μg·L−1,and the sampling volume was 144 m3, the limit of quantification was 1.25 ng·m−3. The recovery rate of standard addition of blank quartz filter membranes was 94.1%-97.5%, with a relative standard deviation ≤3.2%; the recovery rate of standard addition of standard urban particulate matter samples was 93.5%-103.0%, and the relative standard deviation was ≤2.1%, indicating that coexisting components in PM2.5 samples would not affect the determination of tin. For the 10 quartz filter membrane samples of PM2.5 monitoring, the results of tin by the established method (extraction with concentrated hydrochloric acid) were higher than those of the Handbook recommended method (extraction with nitric acid), and the difference is (3.61±0.54) ng·m−3(t=21.303, P<0.05). ConclusionThe established method for the determination of tin and its compounds in PM2.5 by AFS after ultrasonic extraction with concentrated hydrochloric acid is simple, accurate, and suitable for laboratory determination of tin and its compounds in large quantities of PM2.5 samples.
【 授权许可】
Unknown