Heliyon | |
Treatment of industrial wastewater with gamma irradiation for removal of organic load in terms of biological and chemical oxygen demand | |
Toufiq Ahmad1  Mohammad Nafees2  Hina Hina2  | |
[1] Corresponding author.;Department of Environmental Sciences University of Peshawar; | |
关键词: Industrial estate; Wastewater; TSS; BOD; COD; Gamma irradiation; | |
DOI : | |
来源: DOAJ |
【 摘 要 】
Water scarcity is a known and major issue throughout the world. To tackle water scarcity, there is an urgent need for water re-use and recycling through wastewater treatment. This study is an attempt to re-used industrial effluent after treatment with gamma irradiation. The main drain of the industrial estate was sampled and analyzed for Physico-chemical parameters. For treatment, irradiation dose 13 Kilo Gray (kGy) cobalt (Co60) was applied. The treated water was re-analyzed for comparison with pre-analysis and compliance with the National environmental quality standard (NEQS). A decrease was observed in TSS, BOD5, and COD with 79%, 81%, and 85% respectively. The results achieved are within the permissible limits of NEQS. It was concluded that gamma radiation is an instant method for industrial effluent and is herein recommended.
【 授权许可】
Unknown