期刊论文详细信息
Sensors
An Ultrasonic Reverse Time Migration Imaging Method Based on Higher-Order Singular Value Decomposition
Xiang Gao1  Jingpin Jiao1  Jiawei Zhang1  Yuncheng Zhang1 
[1] Faculty of Materials and Manufacturing, Beijing University of Technology, Beijing 100124, China;
关键词: reverse time migration;    higher-order singular value decomposition;    ultrasonic nondestructive testing;    coarse-grained material;    noise reduction;   
DOI  :  10.3390/s22072534
来源: DOAJ
【 摘 要 】

An ultrasonic reverse time migration imaging method, based on high-order singular value decomposition, is proposed in the study to solve the problems of low signal-to-noise ratio (SNR) and excessive artifacts in defect ultrasonic detection imaging results of materials with high noise levels. In this method, based on the 3D structural properties of the ultrasonic full-matrix capture data, higher-order singular value decomposition is directly performed with the 3D data. The method overcomes the difficulty in selecting the number of singular values in the original singular value decomposition noise-reduction algorithm and realizes the one-step noise reduction processing of all the signals. Subsequently, the reverse time migration imaging is performed in the frequency domain, and high-quality acoustic images are obtained. The effects of the number of array elements, the center frequency of the excitation signal, and the number of defects on the denoising effect of the algorithm are investigated. It was experimentally demonstrated that the method could suppress the interference of noise signals and significantly improve the imaging SNR compared with total focusing method and the reverse time migration.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:1次