Applied Sciences | |
Development and Evaluation of a Fluctuating Plume Model for Odor Impact Assessment | |
Federica Capra1  Laura Capelli1  Selena Sironi1  Marzio Invernizzi1  Roberto Sozzi2  | |
[1] Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan, Italy;Independent Researcher, 20133 Milan, Italy; | |
关键词: odor impact assessment; dispersion modelling; peak-to-mean; concentration fluctuation; fluctuating plume model; | |
DOI : 10.3390/app11083310 | |
来源: DOAJ |
【 摘 要 】
For environmental odor nuisance, it is extremely important to identify the instantaneous concentration statistics. In this work, a Fluctuating Plume Model for different statistical moments is proposed. It provides data in terms of mean concentrations, variance, and intensity of concentration. The 90th percentile peak-to-mean factor, R90, was tested here by comparing it with the experimental results (Uttenweiler field experiment), considering different Probability Distribution Functions (PDFs): Gamma and the Modified Weibull. Seventy-two percent of the simulated mean concentration values fell within a factor 2 compared to the experimental ones: the model was judged acceptable. Both the modelled results for standard deviation, σC, and concentration intensity, Ic, overestimate the experimental data. This evidence can be due to the non-ideality of the measurement system. The propagation of those errors to the estimation of R90 is complex, but the ranges covered are quite repeatable: the obtained values are 1–3 for the Gamma, 1.5–4 for Modified Weibull PDF, and experimental ones from 1.4 to 3.6.
【 授权许可】
Unknown