Cogent Engineering | |
Control of active lower limb prosthesis using human-in-the-loop scheme | |
Iván Hernández1  Wen Yu1  | |
[1] Departamento de Control Automático, CINVESTAV-IPN (National Polytechnic Institute), Mexico, Mexico; | |
关键词: Human-model; human-in-the-loop; shared-control; prosthesis; | |
DOI : 10.1080/23311916.2022.2067026 | |
来源: DOAJ |
【 摘 要 】
In many cases robots are directly in touch with humans, this interaction is necessary to design control systems that take into account a human-machine relation. Particularly important is the case when humans share the control with a robot. So, in order to validate control schemes, it is necessary to test them in an environment where the human-machine interaction exists, what could be even dangerous for humans. We present a model of human useful to test controllers, and propose a scheme for human-in-the-loop under shared control. We test the model and the scheme in a lower limb prosthesis that implies naturally a human-machine interaction. Apart from this research, we propose an efficient and low-cost controller for the prosthesis, based on a sensory exoextension and a neuro-decoder consisting of a multilayer perceptrons. The results show the effectiveness of human model to emulate the human interaction.
【 授权许可】
Unknown