期刊论文详细信息
Sustainability
Analyzing the Effect of Parasitic Capacitance in a Full-Bridge Class-D Current Source Rectifier on a High Step-Up Push–Pull Multiresonant Converter
Chainarin Ekkaravarodome1  Viboon Chunkag2  Anusak Bilsalam3  Phatiphat Thounthong4 
[1] Advanced Power Electronics and Experiment Laboratory, Department of Instrumentation and Electronics Engineering, Faculty of Engineering, King Mongkut’s University of Technology North Bangkok (KMUTNB), 1518 Pracharat 1 Rd., Wongsawang, Bang Sue, Bangkok 10800, Thailand;Department Electrical and Computer Engineering, Faculty of Engineering, King Mongkut’s University of Technology North Bangkok (KMUTNB), 1518 Pracharat 1 Rd., Wongsawang, Bang Sue, Bangkok 10800, Thailand;Department of Electrical Engineering Technology, College of Industrial Technology (CIT), King Mongkut’s University of Technology North Bangkok (KMUTNB), 1518 Pracharat 1 Rd., Wongsawang, Bang Sue, Bangkok 10800, Thailand;Renewable Energy Research Centre, Department of Teacher Training in Electrical Engineering, Faculty of Technical Education, King Mongkut’s University of Technology North Bangkok (KMUTNB), 1518 Pracharat 1 Rd., Wongsawang, Bang Sue, Bangkok 10800, Thailand;
关键词: parasitic capacitance;    high step-up;    zero-current switching;    multiresonant;    converter;    current source rectifier;   
DOI  :  10.3390/su13105477
来源: DOAJ
【 摘 要 】

This paper presents an analysis on the effect of a parasitic capacitance full-bridge class-D current source rectifier (FB-CDCSR) on a high step-up push–pull multiresonant converter (HSPPMRC). The proposed converter can provide high voltage for a 12 VDC battery using an isolated transformer and an FB-CDCSR. The main switches of the push–pull and diode full-bridge rectifier can be operated under a zero-current switching condition (ZCS). The advantages of this technique are that it uses a leakage inductance to achieve the ZCS for the power switch, and the leakage inductance and parasitic junction capacitance are used to design the secondary side of the resonant circuit. A prototype HSPPMRC was built and operated at 200 kHz fixed switching frequency, 340 VDC output voltage, and 250 W output power. In addition, the efficiency is equal to 96% at maximum load. Analysis of the effect of the parasitic junction capacitance on the full-bridge rectifier indicates that it has a significant impact on the operating point of the resonant tank and voltage. The proposed circuit design was verified via experimental results, which were found to be in agreement with the theoretical analysis.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次