Cancer Imaging | |
Diagnostic efficiency of whole-body 18F-FDG PET/MRI, MRI alone, and SUV and ADC values in staging of primary uterine cervical cancer | |
Sara Narva1  Johanna Hynninen1  Sakari Hietanen1  Irina Rinta-Kiikka2  Johanna Virtanen3  Aida Steiner3  | |
[1] Department of Obstetrics and Gynecology, Turku University Hospital;Department of Radiology, Tampere University Hospital;Department of Radiology, Turku University Hospital and University of Turku; | |
关键词: PET/MRI; 3 T MRI; Cervical cancer; Staging; SUV; ADC; | |
DOI : 10.1186/s40644-020-00372-5 | |
来源: DOAJ |
【 摘 要 】
Abstract Background The use of PET/MRI for gynecological cancers is emerging. The purpose of this study was to assess the additional diagnostic value of PET over MRI alone in local and whole-body staging of cervical cancer, and to evaluate the benefit of standardized uptake value (SUV) and apparent diffusion coefficient (ADC) in staging. Methods Patients with histopathologically-proven cervical cancer and whole-body 18F-FDG PET/MRI obtained before definitive treatment were retrospectively registered. Local tumor spread, nodal involvement, and distant metastases were evaluated using PET/MRI or MRI dataset alone. Histopathology or clinical consensus with follow-up imaging were used as reference standard. Tumor SUVmax and ADC were measured and SUVmax/ADC ratio calculated. Area under the curve (AUC) was determined to predict diagnostic performance and Mann-Whitney U test was applied for group comparisons. Results In total, 33 patients who underwent surgery (n = 23) or first-line chemoradiation (n = 10) were included. PET/MRI resulted in higher AUC compared with MRI alone in detecting parametrial (0.89 versus 0.73), vaginal (0.85 versus 0.74), and deep cervical stromal invasion (0.96 versus 0.74), respectively. PET/MRI had higher diagnostic confidence than MRI in identifying patients with radical cone biopsy and no residual at hysterectomy (sensitivity 89% versus 44%). PET/MRI and MRI showed equal AUC for pelvic nodal staging (both 0.73), whereas AUC for distant metastases was higher using PET/MRI (0.80 versus 0.67). Tumor SUVmax/ADC ratio, but not SUVmax or ADC alone, was significantly higher in the presence of metastatic pelvic lymph nodes (P < 0.05). Conclusions PET/MRI shows higher accuracy than MRI alone for determining local tumor spread and distant metastasis emphasizing the added value of PET over MRI alone in staging of cervical cancer. Tumor SUVmax/ADC ratio may predict pelvic nodal involvement.
【 授权许可】
Unknown