期刊论文详细信息
BMC Musculoskeletal Disorders
Inter- and intra-observer reliability of clinical movement-control tests for marines
关键词: Military;    Motor control;    Reproducibility;    Screening;    Sensitivity;    Specificity;    Validity;   
DOI  :  10.1186/1471-2474-13-263
来源: DOAJ
【 摘 要 】

Abstract

Background

Musculoskeletal disorders particularly in the back and lower extremities are common among marines. Here, movement-control tests are considered clinically useful for screening and follow-up evaluation. However, few studies have addressed the reliability of clinical tests, and no such published data exists for marines. The present aim was therefore to determine the inter- and intra-observer reliability of clinically convenient tests emphasizing movement control of the back and hip among marines. A secondary aim was to investigate the sensitivity and specificity of these clinical tests for discriminating musculoskeletal pain disorders in this group of military personnel.

Methods

This inter- and intra-observer reliability study used a test-retest approach with six standardized clinical tests focusing on movement control for back and hip. Thirty-three marines (age 28.7 yrs, SD 5.9) on active duty volunteered and were recruited. They followed an in-vivo observation test procedure that covered both low- and high-load (threshold) tasks relevant for marines on operational duty. Two independent observers simultaneously rated performance as “correct” or “incorrect” following a standardized assessment protocol. Re-testing followed 7–10 days thereafter. Reliability was analysed using kappa (κ) coefficients, while discriminative power of the best-fitting tests for back- and lower-extremity pain was assessed using a multiple-variable regression model.

Results

Inter-observer reliability for the six tests was moderate to almost perfect with κ-coefficients ranging between 0.56-0.95. Three tests reached almost perfect inter-observer reliability with mean κ-coefficients > 0.81. However, intra-observer reliability was fair-to-moderate with mean κ-coefficients between 0.22-0.58. Three tests achieved moderate intra-observer reliability with κ-coefficients > 0.41. Combinations of one low- and one high-threshold test best discriminated prior back pain, but results were inconsistent for lower-extremity pain.

Conclusions

Our results suggest that clinical tests of movement control of back and hip are reliable for use in screening protocols using several observers with marines. However, test-retest reproducibility was less accurate, which should be considered in follow-up evaluations. The results also indicate that combinations of low- and high-threshold tests have discriminative validity for prior back pain, but were inconclusive for lower-extremity pain.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次