期刊论文详细信息
Journal of Clinical Medicine
Accuracy of Computer-Assisted Surgery in Maxillary Reconstruction: A Systematic Review
FrankK. J. Leusink1  GustaafJ. C.van Baar1  Tymour Forouzanfar1  Lars Leeuwrik1  Angela Ridwan-Pramana1  Kitty Schipper1  HenriA. H. Winters2 
[1] Department of Oral and Maxillofacial Surgery/Pathology, Amsterdam UMC and Academic Center for Dentistry Amsterdam (ACTA), Vrije Universiteit Amsterdam, De Boelelaan 1117, 1081 HV Amsterdam, The Netherlands;Department of Plastic, Reconstructive and Hand Surgery, Amsterdam UMC, Vrije Universiteit Amsterdam, De Boelelaan 1117, 1081 HV Amsterdam, The Netherlands;
关键词: maxillofacial reconstruction;    free tissue flaps;    surgery;    computer-assisted;    computer-aided design;    computer-aided manufacturing;   
DOI  :  10.3390/jcm10061226
来源: DOAJ
【 摘 要 】

Computer-assisted surgery (CAS) in maxillary reconstruction has proven its value regarding more predictable postoperative results. However, the accuracy evaluation methods differ between studies, and no meta-analysis has been performed yet. A systematic review was performed in the PubMed, Embase, and Cochrane Library databases, using a Patient, Intervention, Comparison and Outcome (PICO) method: (P) patients in need of maxillary reconstruction using free osteocutaneous tissue transfer, (I) reconstructed according to a virtual plan in CAS software, (C) compared to the actual postoperative result, and (O) postoperatively measured by a quantitative accuracy assessment) search strategy, and was reported according to the PRISMA statement. We reviewed all of the studies that quantitatively assessed the accuracy of maxillary reconstructions using CAS. Twelve studies matched the inclusion criteria, reporting 67 maxillary reconstructions. All of the included studies compared postoperative 3D models to preoperative 3D models (revised to the virtual plan). The postoperative accuracy measurements mainly focused on the position of the fibular bony segments. Only approximate comparisons of postoperative accuracy between studies were feasible because of small differences in the postoperative measurement methods; the accuracy of the bony segment positioning ranged between 0.44 mm and 7.8 mm, and between 2.90° and 6.96°. A postoperative evaluation guideline to create uniformity in evaluation methods needs to be considered so as to allow for valid comparisons of postoperative results and to facilitate meta-analyses in the future. With the proper validation of the postoperative results, future research might explore more definitive evidence regarding the management and superiority of CAS in maxillary and midface reconstruction.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次