| Âderna Fìzika ta Energetika | |
| Method of direct measurement of the capture neutron cross section for radioactive nuclei | |
| V. M. Shevel1  V. I. Slisenko1  Yu. G. Schepkin1  | |
| [1] Institute for Nuclear Research, National Academy of Sciences of Ukraine, Kyiv, Ukraine; | |
| 关键词: neutron; radioactive capture; cross section; spectrometry; multiplicity; gamma-radiation; detector.; | |
| DOI : | |
| 来源: DOAJ | |
【 摘 要 】
Method of direct measurement of the capture neutron cross section for radioactive nuclei on the base of the multiplicity spectrometry of the capture gamma radiation was realized by means of the 4π-multisection detector. The energy of gamma rays of the radioactive irradiation must not exceed not more 1 MeV. Capacity methods had been examinated for the thermal neutron cross section measurement. Methods sensitivity on the minimum quantity of measuring sample with capture cross section 40 barns equal to 0,37 mg and maximum specific activity on the 137Cs of the measuring sample is around 0,44 · 1010 Bq*g-1.
【 授权许可】
Unknown