期刊论文详细信息
Sensors
A New Method of Using Sensor Arrays for Gas Leakage Location Based on Correlation of the Time-Space Domain of Continuous Ultrasound
Yibo Li1  Xiaoyue Gong1  Yu Zhang1  Shijiu Jin1  Xu Bian1 
[1] State Key Laboratory of Precision Measurement Technology and Instrument, Tianjin University, Tianjin 300072, China;
关键词: continuous ultrasound;    gas leakage;    location;    real time;    dispersion;    sensor array;   
DOI  :  10.3390/s150408266
来源: DOAJ
【 摘 要 】

This paper proposes a time-space domain correlation-based method for gas leakage detection and location. It acquires the propagated signal on the skin of the plate by using a piezoelectric acoustic emission (AE) sensor array. The signal generated from the gas leakage hole (which diameter is less than 2 mm) is time continuous. By collecting and analyzing signals from different sensors’ positions in the array, the correlation among those signals in the time-space domain can be achieved. Then, the directional relationship between the sensor array and the leakage source can be calculated. The method successfully solves the real-time orientation problem of continuous ultrasonic signals generated from leakage sources (the orientation time is about 15 s once), and acquires high accuracy location information of leakage sources by the combination of multiple sets of orientation results. According to the experimental results, the mean value of the location absolute error is5.83 mm on a one square meter plate, and the maximum location error is generally within a ±10 mm interval. Meanwhile, the error variance is less than 20.17.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:1次