期刊论文详细信息
Frontiers in Energy Research
Mechanical Booster Pump-Assisted Thermochemical Mode for Low-Grade Heat Storage and Upgrading: A Thermodynamic Study
Noriyuki Kobayashi1  Rongjun Wu1  Jun Li4  Tao Zeng4  Zhaohong He4  Lisheng Deng4  Hongyu Huang4 
[1] Department of Chemical Systems Engineering, Nagoya University, Nagoya, Japan;Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou, China;Key Laboratory of Renewable Energy, Chinese Academy of Sciences, Guangzhou, China;Southern Marine Science and Engineering Guangdong Laboratory (Guangzhou), Guangzhou, China;
关键词: thermochemical heat storage;    low-grade heat;    mechanical booster pump;    thermodynamic analysis;    heat upgrading;   
DOI  :  10.3389/fenrg.2022.851611
来源: DOAJ
【 摘 要 】

To assure stable and dependable functioning of the thermochemical energy storage (TCES) system under unstable low-grade heat temperatures, three mechanical booster pump-assisted TCES (MBP-assisted TCES) modes operating with SrBr2·H2O/H2O, LiOH/H2O, and CaCl2·H2O/H2O are proposed for the application of heat storage and upgrading. The operating modes are the MBP-assisted charging mode (A mode), MBP-assisted discharging mode (B mode), and MBP-assisted charging and discharging mode (C mode). A thermodynamic model is established to evaluate the influences of condensing temperature, compression ratio, MBP isentropic efficiency, and reaction advancement on the heat source temperature and system performance from both energy and exergy perspectives. The results indicate that compared with the other two modes, the B mode is more effective in reducing the heat source temperature and achieving better system performance. Compared to the conventional TCES mode, the proposed modes can operate at lower heat source temperatures that can be minimized by up to 21∼25°C by employing the B mode with a compression ratio of 3.0 at the condensing temperature of 24°C. The B mode with SrBr2·H2O/H2O exhibits the highest energy and exergy efficiencies that the coefficients of performance based on total energy input and electric power consumed (COPtotal and COPelec), and exergy efficiency varies in the range of 0.53∼0.59, 7.4∼19.6, and 0.78∼0.95, respectively. In contrast, CaCl2·H2O/H2O shows the lowest system performance, but a higher heat output temperature can be required. In addition, to maintain the MBP discharge temperature below 180°C, there is a maximum permitted compression ratio that varies depending on the operating modes, operating conditions, and working pairs. The findings of this research can be used as theoretical references and suggestions for selecting MBP-assisted TCES modes, operating conditions, and working pairs for low-grade heat storage and upgrading.

【 授权许可】

Unknown   

  文献评价指标  