Energy Reports | |
Research on three-phase four-wire NPC converter for Tokamak low-frequency resonance suppressor | |
Liang Tan1  Mingyan Dai2  Ge Gao2  Jun Qu2  Jie Yang3  Jing Lu3  Yanan Wu3  Jiansheng Wang3  Zhiwei Mao3  Xianshun Shen3  | |
[1] Corresponding author.;University of Science and Technology of China, Hefei 230026, China;Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, China; | |
关键词: Tokamak power system; Low-frequency resonance suppressor; Three-phase four-wire converter; Control strategy; | |
DOI : | |
来源: DOAJ |
【 摘 要 】
During the operation of Tokamak power system, a large number of low frequency harmonic currents with complex spectrum will be generated. Low-frequency resonance suppressor is an effective solution to suppress this low-frequency harmonic currents. The low-frequency harmonic suppression theory of low-frequency resonance suppressor is analyzed in this paper. Meanwhile, the state space equation of three-phase four-wire neutral-point-clamped rectifier is established in the LFRS. According to the mathematical model, the double closed-loop and zero sequence current control strategies are proposed to improve power factor operation on AC side and neutral point potential balance control on DC side of three-phase four-wire converter. The results show the correctness of the theoretical analysis and provide a technical reference for suppression of low-frequency harmonics of other Tokamak devices.
【 授权许可】
Unknown