期刊论文详细信息
IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
An Approach for Evaluating Multisite Radiometry Calibration of Sentinel-2B/MSI Using RadCalNet Sites
Qijin Han1  Enyu Zhao2  Yaokai Liu3  Shi Qiu3  Lingling Ma3  Caixia Gao3  Yongguang Zhao3  Yonggang Qian3  Chuanrong Li3  Ning Wang3  Zhifeng Wu4 
[1] China Centre for Resources Satellite Data and Application, Beijing, China;College of Information Science and Technology, Dalian Maritime University, Dalian, China;Key Laboratory of Quantitative Remote Sensing Information Technology, Academy of Opto-Electronics, Chinese Academy of Sciences, Beijing, China;National Institute of Metrology, Beijing, China;
关键词: Field calibration;    Monte Carlo;    radiometric calibration network (RadCalNet);    Sentinel-2B/multispectral instrument (MSI);    uncertainty analysis;   
DOI  :  10.1109/JSTARS.2021.3102271
来源: DOAJ
【 摘 要 】

The Sentinel-2B offers high spatial resolution optical imagery from 13 bands in the visible, near infrared, and short-wave infrared range of the electromagnetic spectrum, providing enhanced continuity to monitoring global terrestrial surfaces and coastal waters. In this article, its radiometry calibration is evaluated using 37 clear-sky observations in 2018 from the four sites of radiometric calibration network for assuring data quality. However, since the single calibration results acquired under different surface and atmospheric conditions have different biases and different uncertainties, it is difficult to determine which calibration sample is much more trustable. In view of this, by assuming that the calibration samples are independent of each other, a state-of-the-art reference value is derived by combining 37 calibration samples using a weighted average method, which has much lower uncertainty and approaches the “true” value. The reference value also could be used to compare each calibration result. The result shows that the reference value of the relative difference between the simulated and observed top-of-atmosphere reflectance is 4.29%, 4.95%, 4.54%, 5.34%, respectively, for bands 2, 3, 4, and 8, and the corresponding uncertainty is 1.09%, 1.10%, 1.10%, and 1.12%, respectively; the degree of equivalence for each sample is calculated by comparing each calibration result with the reference value. It is worth noting that the degrees of equivalence are lower than 5%, and the four samples on July 9, July 13, October 4, and October 11 perform worse than the other sample.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:4次