期刊论文详细信息
Water Science and Engineering
Optimal sensor placement in hydropower house based on improved triaxial effective independence method
关键词: triaxial sensor;    optimal placement;    EfI3-DPR3 method;    hydropower house;    vibration testing;   
DOI  :  10.3882/j.issn.1674-2370.2012.03.008
来源: DOAJ
【 摘 要 】

The capacity and size of hydro-generator units are increasing with the rapid development of hydroelectric enterprises, and the vibration of the powerhouse structure has increasingly become a major problem. Field testing is an important method for research on dynamic identification and vibration mechanisms. Research on optimal sensor placement has become a very important topic due to the need to obtain effective testing information from limited test resources. To overcome inadequacies of the present methods, this paper puts forward the triaxial effective independence driving-point residue (EfI3-DPR3) method for optimal sensor placement. The EfI3-DPR3 method can incorporate both the maximum triaxial modal kinetic energy and linear independence of the triaxial target modes at the selected nodes. It was applied to the optimal placement of triaxial sensors for vibration testing in a hydropower house, and satisfactory results were obtained. This method can provide some guidance for optimal placement of triaxial sensors of underground powerhouses.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次