期刊论文详细信息
Acta Polytechnica
Fire Resistance of Axially Loaded Slender Concrete Filled Steel Tubular Columns – Development of a Three-Dimensional Numerical Model and Comparison with Eurocode 4
关键词: Fire resistance;    concrete filled steel tubular columns;    finite element analysis;   
DOI  :  
来源: DOAJ
【 摘 要 】

In recent years, concrete filled tubular (CFT) columns have become popular among designers and structural engineers, due to a series of highly appreciated advantages: high load-bearing capacity, high seismic resistance, attractive appearance, reduced column footing, fast construction technology and high fire resistance without external protection. In a fire, the degradation of the material properties will cause CFT columns to become highly nonlinear and inelastic, which makes it quite difficult to predict their failure. In fact, it is still not possible for analytical methods to predict with enough accuracy the behaviour of columns of this kind when exposed to fire. Numerical models are therefore widely sought. Many numerical simulations have been carried out worldwide, without obtaining satisfactory results. This work proposes a three-dimensional numerical model for studying the actual fire behaviour of columns of this kind. This model was validated by comparing the simulation results with fire resistance tests carried out by other researchers, as well as with the predictions of the Eurocode 4 simplified calculation model.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:1次