Journal of Modern Power Systems and Clean Energy | |
Derivation and conformity measurement of a popular explicit analytic Borowy 2C PV module model | |
Jianmin Zhang1  Qianzhi Zhang2  | |
[1] School of Automation, Hangzhou Dianzi University,Hangzhou,China,310017;School of Electrical, Computer, and Energy Engineering, Ira A. Fulton Schools of Engineering, Arizona State University,Tempe,AZ,USA,85287-5706; | |
关键词: Photovoltaic module; Analytic model; Explicit model; Implicit model; Borowy model; Conformity check; | |
DOI : 10.1007/s40565-014-0085-8 | |
来源: DOAJ |
【 摘 要 】
A popular explicit analytic Borowy 2C PV module model is proposed for power generation prediction. The maximum power point and the open-circuit point which are calculated in this model cannot be equal to the data given by manufacturers under standard test condition (STC). The derivation of this model has never been mentioned in any literatures. The parameter forms of 2C model in this paper are more simplified, and the model is decomposed into a STC sub-model and an incremental sub-model. The STC model is derived successfully from an ideal single-diode circuit model. Relative error estimations are developed to do the conformity error measurements. The analysis results showed that though the biases at those critical points are very small, the conformity will depend on both of the two ratio values