期刊论文详细信息
Trials
Comparison of two metaphyseal-fitting (short) femoral stems in primary total hip arthroplasty: study protocol for a prospective randomized clinical trial with additional biomechanical testing and finite element analysis
G. Sakellaropoulos1  I. Diamantakos2  Sp Pantelakis2  I. Tatani3  P. Megas3  A. Panagopoulos3 
[1] Department of Medical Physics, School of Medicine, University of Patras;Laboratory of Technology and Strength of Materials, Department of Mechanical Engineering and Aeronautics, University of Patras;Orthopaedic Department, University Hospital of Patras;
关键词: Total hip arthroplasty;    Short stem;    Biomechanical testing;    Finite element analysis;    Clinical outcome;   
DOI  :  10.1186/s13063-019-3445-x
来源: DOAJ
【 摘 要 】

Abstract Background Total hip replacement has recently followed a progressive evolution towards principles of bone- and soft-tissue-sparing surgery. Regarding femoral implants, different stem designs have been developed as an alternative to conventional stems, and there is a renewed interest towards short versions of uncemented femoral implants. Based on both experimental testing and finite element modeling, the proposed study has been designed to compare the biomechanical properties and clinical performance of the newly introduced short-stem Minima S, for which clinical data are lacking with an older generation stem, the Trilock Bone Preservation Stem with an established performance record in short to midterm follow-up. Methods/design In the experimental study, the transmission of forces as measured by cortical surface-strain distribution in the proximal femur will be evaluated using digital image correlation (DIC), first on the non-implanted femur and then on the implanted stems. Finite element parametric models of the bone, the stem and their interface will be also developed. Finite element predictions of surface strains in implanted composite femurs, after being validated against biomechanical testing measurements, will be used to assist the comparison of the stems by deriving important data on the developed stress and strain fields, which cannot be measured through biomechanical testing. Finally, a prospective randomized comparative clinical study between these two stems will be also conducted to determine (1) their clinical performance up to 2 years’ follow-up using clinical scores and gait analysis (2) stem fixation and remodeling using a detailed radiographic analysis and (3) incidence and types of complications. Discussion Our study would be the first that compares not only the clinical and radiological outcome but also the biomechanical properties of two differently designed femoral implants that are theoretically classified in the same main category of cervico-metaphyseal-diaphyseal short stems. We can hypothesize that even these subtle variations in geometric design between these two stems may create different loading characteristics and thus dissimilar biomechanical behaviors, which in turn could have an influence to their clinical performance. Trial registration International Standard Randomized Controlled Trial Number, ID: ISRCTN10096716. Retrospectively registered on May 8 2018.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:5次