期刊论文详细信息
Inżynieria Ekologiczna
APPLICATION OF FENTON’S PROCESS FOR TREATMENT OF TANNERY WASTEWATER
Lucyna Bogumiła Przywara1 
[1] Akademia Techniczno-Humanistyczna, ul. Willowa 2, 43-309 Bielsko-Biała;
关键词: Tannery wastewater;    COD removal;    Fenton’s reagent;   
DOI  :  10.12912/23920629/68321
来源: DOAJ
【 摘 要 】

The aim of this study was to treat of tannery wastewater with the chemical advanced oxidation using Fenton reagent. Advanced oxidation process was carried out using different doses of iron (Fe2+) changes from 0.056 g Fe2+/dm3 to 0.56 g Fe2+/dm3 and H2O2 from 0.34 g/dm3 to 5.44 g/dm3. The wastewater samples were characterized for the concentration of chemical oxygen demand (COD), chromium, ammonia and pH, conductivity. The possibility of using the coagulation process using SAX 18was also investigated. The efficiency of the applied processes was monitored by change mainly of chemical oxygen demand (COD). The maximum COD removal was 80% for Fenton’s oxidation process at pH 3.0, Fe2+ (0.56 g Fe2+/dm3) and H2O2 (4.08 g/dm3) and significantly higher than in the case of the coagulation process.

【 授权许可】

Unknown   

  文献评价指标  