[1] Department of Diagnostic Imaging, William Osler Health System;Department of Emergency Medicine, William Osler Health System;Department of Family Medicine, McMaster University;Department of Family and Community Medicine, University of Toronto;Division of Emergency Medicine, McMaster University, Hamilton Health Sciences, McMaster Clinic;
关键词: Pulmonary embolism;    Physicians practice patterns;    Computed tomography;    Biomarkers;    Quality improvement;   
DOI  :  10.1186/s12873-021-00401-x
来源: DOAJ
【 摘 要 】

Abstract Background A variety of evidence-based algorithms and decision rules using D-Dimer testing have been proposed as instruments to allow physicians to safely rule out a pulmonary embolism (PE) in low-risk patients. Objective To describe the prevalence of D-Dimer utilization among emergency department (ED) physicians and its impact on positive yields and utilization rates of Computed Tomography Pulmonary Angiography (CTPA). Methods Data was collected on all CTPA studies ordered by ED physicians at three sites during a 2-year period. Using a chi-square test, we compared the diagnostic yield for those patients who had a D-Dimer prior to their CTPA and those who did not. Secondary analysis was done to examine the impact of D-Dimer testing prior to CTPA on individual physician diagnostic yield or utilization rate. Results A total of 2811 CTPAs were included in the analysis. Of these, 964 CTPAs (34.3%) were ordered without a D-Dimer, and 343 (18.7%) underwent a CTPA despite a negative D-Dimer. Those CTPAs preceded by a D-Dimer showed no significant difference in positive yields when compared to those ordered without a D-Dimer (9.9% versus 11.3%, p = 0.26). At the individual physician level, no statistically significant relationship was found between D-Dimer utilization and CTPA utilization rate or diagnostic yield. Conclusion This study provides evidence of suboptimal adherence to guidelines in terms of D-Dimer screening prior to CTPA, and forgoing CTPAs in patients with negative D-Dimers. However, the lack of a positive impact of D-Dimer testing on either CTPA diagnostic yield or utilization rate is indicative of issues relating to the high false-positive rates associated with D-Dimer screening.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次