The XTRA Option at the NEUTRA Facility—More Than 10 Years of Bi-Modal Neutron and X-ray Imaging at PSI | |
David Mannes1  Jan Hovind1  EberhardH. Lehmann1  AndersP. Kaestner1  Pavel Trtik1  Markus Strobl1  | |
[1] Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, CH-5232 Villigen, Switzerland; | |
关键词: thermal neutrons; X-ray; radiography; tomography; data fusion; attenuation coefficients; | |
DOI : 10.3390/app11093825 | |
来源: DOAJ |
【 摘 要 】
Just after the start into the new millennium the concept for combined neutron and X-ray imaging was introduced by extending the standard configuration of the thermal neutron imaging NEUTRA instrument with a complementary 320 kV X-ray tube setup. Using essentially the same detector configuration for both neutron and X-ray imaging enables a pixel-wise (in radiography) and a voxel-wise (in tomography) correlation and combination of attenuation data. The optimal use and analyses of such complementary data sets depend on the specific investigation and research question and range from a combinatory interpretation of separately analyzed images to full data fusion approaches. Here, several examples from more than a decade of bimodal neutron and X-ray imaging at NEUTRA at PSI shall be reviewed.