期刊论文详细信息
BMC Musculoskeletal Disorders
How to improve the safety of bicortical pedicle screw insertion in the thoracolumbar vertebrae: analysis base on three-dimensional CT reconstruction of patients in the prone position
Xiuling Huang1  Yanchen CHU2  Wenjiu Yang2  Qingxian Hou2  Zhijie Wang2  Chao Xu3  Jinglong Ma3 
[1] Clinical Labororatory, The Affiliated Hospital of Qingdao University;Department of Spine Surgery, The Affiliated Hospital of Qingdao University;Qingdao University Medical College;
关键词: Pedicle screw insertion;    Bicortical anchorage;    Thoracic and lumbar spine disease;    Aorta;    Inferior vena cava;    Prone CT three-dimensional reconstruction;   
DOI  :  10.1186/s12891-020-03473-1
来源: DOAJ
【 摘 要 】

Abstract Background Through the comparison of three-dimensional CT reconstruction between the supine position and the prone position, the relative position of thoracolumbar great vessels and vertebral body was studied, and the shortest safe distance between them was measured to improve the safety of bicortical pedicle screw insertion and reduce the risk of vascular injury. Methods Forty adults were selected to participate the research. Three-dimensional reconstruction of thoracolumbar (T9-L3) CT was performed in the prone position and the supine position. The relative distance between the Aorta/Inferior Vena Cava (IVC) and vertebral body was obtained as AVD/VVD respectively. The relative angle of the Aorta/ IVC and the vertebral body was calculated as ∠AOY/∠VOY. Self-controlled experiments were carried out in the prone and the supine positions, and the data obtained were analyzed using SPSS 22.0 statistical software. Results The AVD of the prone position and the supine position was the shortest at T12 (3.18 ± 0.68 mm), but the difference was not statistically significant. The aorta of the T9-L3 segment was shifted from the anterolateral to the anteromedial. The ∠AOY of the other groups differed significantly between the prone and supine positions in all vertebrae except T12 and L1 (P < 0.05), and the aorta in the prone position was more anteromedial than that of supine position. With regard to VVD/∠VOY, there was no significant difference between the prone and supine positions (P ≥ 0.05), and the minimum VVD of L3 segment is greater than 5.4 mm. The IVC has no obvious mobility and is fixed in the range of 20 ° ~ 30 ° near the midline. Conclusion When using bicortical anchoring of pedicle screws, it is safe to ensure that the protruding tips of the screw is less than 3 mm. Due to the mobility of the aorta in different postures and individual differences in anatomy, the prone position CT can help doctors to make better preoperative plans and decisions.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次