期刊论文详细信息
Journal of the American Heart Association: Cardiovascular and Cerebrovascular Disease
Ultrathin Strut Biodegradable Polymer Sirolimus‐Eluting Stent Versus Durable‐Polymer Everolimus‐Eluting Stent for Percutaneous Coronary Revascularization: 2‐Year Results of the BIOSCIENCE Trial
André Vuilliomenet1  Peiman Jamshidi2  Daniel Weilenmann3  Anna Franzone4  Thomas Pilgrim4  Stephan Windecker4  Raffaele Piccolo4  Rainer Zbinden5  Franz Eberli5  David J. Kurz5  Christoph Kaiser6  Stéphane Cook7  Marco Roffi8  Olivier Muller9  Peter Jüni1,10  Dik Heg1,11 
[1] Department of Cardiology, Kantonsspital, Aarau, Switzerland;Department of Cardiology, Kantonsspital, Luzern, Switzerland;Department of Cardiology, Kantonsspital, St. Gallen, Switzerland;Department of Cardiology, Swiss Cardiovascular Center, University Hospital, Bern, Switzerland;Department of Cardiology, Triemlispital, Zurich, Switzerland;Department of Cardiology, University Hospital, Basel, Switzerland;Department of Cardiology, University Hospital, Fribourg;Department of Cardiology, University Hospital, Geneva, Switzerland;Department of Cardiology, University Hospital, Lausanne, Switzerland;Institute of Primary Health Care (BIHAM), University of Bern, Bern, Switzerland;Institute of Social and Preventive Medicine and Clinical Trials Unit, Bern University Hospital, Bern, Switzerland;
关键词: biodegradable polymer;    drug‐eluting stent;    everolimus‐eluting stent;    percutaneous coronary intervention;    sirolimus‐eluting stent;   
DOI  :  10.1161/JAHA.116.003255
来源: DOAJ
【 摘 要 】

BackgroundNo data are available on the long‐term performance of ultrathin strut biodegradable polymer sirolimus‐eluting stents (BP‐SES). We reported 2‐year clinical outcomes of the BIOSCIENCE (Ultrathin Strut Biodegradable Polymer Sirolimus‐Eluting Stent Versus Durable Polymer Everolimus‐Eluting Stent for Percutaneous Coronary Revascularisation) trial, which compared BP‐SES with durable‐polymer everolimus‐eluting stents (DP‐EES) in patients undergoing percutaneous coronary intervention. Methods and ResultsA total of 2119 patients with minimal exclusion criteria were assigned to treatment with BP‐SES (n=1063) or DP‐EES (n=1056). Follow‐up at 2 years was available for 2048 patients (97%). The primary end point was target‐lesion failure, a composite of cardiac death, target‐vessel myocardial infarction, or clinically indicated target‐lesion revascularization. At 2 years, target‐lesion failure occurred in 107 patients (10.5%) in the BP‐SES arm and 107 patients (10.4%) in the DP‐EES arm (risk ratio [RR] 1.00, 95% CI 0.77–1.31, P=0.979). There were no significant differences between BP‐SES and DP‐EES with respect to cardiac death (RR 1.01, 95% CI 0.62–1.63, P=0.984), target‐vessel myocardial infarction (RR 0.91, 95% CI 0.60–1.39, P=0.669), target‐lesion revascularization (RR 1.17, 95% CI 0.81–1.71, P=0.403), and definite stent thrombosis (RR 1.38, 95% CI 0.56–3.44, P=0.485). There were 2 cases (0.2%) of definite very late stent thrombosis in the BP‐SES arm and 4 cases (0.4%) in the DP‐EES arm (P=0.423). In the prespecified subgroup of patients with ST‐segment elevation myocardial infarction, BP‐SES was associated with a lower risk of target‐lesion failure compared with DP‐EES (RR 0.48, 95% CI 0.23–0.99, P=0.043, Pinteraction=0.026). ConclusionsComparable safety and efficacy profiles of BP‐SES and DP‐EES were maintained throughout 2 years of follow‐up. Clinical Trial RegistrationURL: https://www.clinicaltrials.gov. Unique identifier: NCT01443104.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次