期刊论文详细信息
Journal of Cardiovascular Magnetic Resonance
Fully-automated global and segmental strain analysis of DENSE cardiovascular magnetic resonance using deep learning for segmentation and phase unwrapping
Andrew D. Scott1  Changyu Sun2  Xue Feng2  Sona Ghadimi2  Craig H. Meyer2  Daniel A. Auger2  Frederick H. Epstein2  Jie Jane Cao3  Kenneth C. Bilchick4  John N. Oshinski5  Daniel B. Ennis6 
[1]Cardiovascular Magnetic Resonance Unit, The Royal Brompton Hospital
[2]Department of Biomedical Engineering, University of Virginia
[3]Department of Cardiology, St. Francis Hospital
[4]Department of Medicine, University of Virginia Health System
[5]Department of Radiology and Imaging Sciences, Emory University School of Medicine
[6]Department of Radiology, Stanford University
关键词: DENSE;    Cardiac MRI;    Machine learning;    Deep learning;    Phase unwrapping;    Strain analysis;   
DOI  :  10.1186/s12968-021-00712-9
来源: DOAJ
【 摘 要 】
Abstract Background Cardiovascular magnetic resonance (CMR) cine displacement encoding with stimulated echoes (DENSE) measures heart motion by encoding myocardial displacement into the signal phase, facilitating high accuracy and reproducibility of global and segmental myocardial strain and providing benefits in clinical performance. While conventional methods for strain analysis of DENSE images are faster than those for myocardial tagging, they still require manual user assistance. The present study developed and evaluated deep learning methods for fully-automatic DENSE strain analysis. Methods Convolutional neural networks (CNNs) were developed and trained to (a) identify the left-ventricular (LV) epicardial and endocardial borders, (b) identify the anterior right-ventricular (RV)-LV insertion point, and (c) perform phase unwrapping. Subsequent conventional automatic steps were employed to compute strain. The networks were trained using 12,415 short-axis DENSE images from 45 healthy subjects and 19 heart disease patients and were tested using 10,510 images from 25 healthy subjects and 19 patients. Each individual CNN was evaluated, and the end-to-end fully-automatic deep learning pipeline was compared to conventional user-assisted DENSE analysis using linear correlation and Bland Altman analysis of circumferential strain. Results LV myocardial segmentation U-Nets achieved a DICE similarity coefficient of 0.87 ± 0.04, a Hausdorff distance of 2.7 ± 1.0 pixels, and a mean surface distance of 0.41 ± 0.29 pixels in comparison with manual LV myocardial segmentation by an expert. The anterior RV-LV insertion point was detected within 1.38 ± 0.9 pixels compared to manually annotated data. The phase-unwrapping U-Net had similar or lower mean squared error vs. ground-truth data compared to the conventional path-following method for images with typical signal-to-noise ratio (SNR) or low SNR (p < 0.05), respectively. Bland–Altman analyses showed biases of 0.00 ± 0.03 and limits of agreement of − 0.04 to 0.05 or better for deep learning-based fully-automatic global and segmental end-systolic circumferential strain vs. conventional user-assisted methods. Conclusions Deep learning enables fully-automatic global and segmental circumferential strain analysis of DENSE CMR providing excellent agreement with conventional user-assisted methods. Deep learning-based automatic strain analysis may facilitate greater clinical use of DENSE for the quantification of global and segmental strain in patients with cardiac disease.
【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:1次