Measurement of TOF of fast neutrons with 238U target
Hongbin Zhang1  Junwei Zhang2  Zhiyong He2  Yuanfan Guan2  Peng Ma2  Limin Duan2  Chunli Yang2  Tianli Qiu2  Xianglun Wei3  Yikai Hou3  Rongjiang Hu3  Liang Chen3  Chengui Lu3  Xiaohua Yuan3  Meng Li3  Zaiguo Gan3  Herun Yang4 
[1] Corresponding author. Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, 730000, China.;School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing, 100049, China;Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, 730000, China;North China University of Water Resources and Electric Power, Zhengzhou, 450000, China;
关键词: Parallel plate avalanche counter;    The time resolution;    Neutron;    Time-of-flight(TOF);   
DOI  :  
来源: DOAJ
【 摘 要 】

We developed a Dual-PPACs detector for fast neutron measurements that consists of two sets of PPAC: conventional PPAC and fission PPAC. A238U(U3O8) coating is placed in the fission PPAC’s anode, which is used as the neutrons conversion layer. An experiment was performed to measure neutron time-of-flight (TOF) in which 252Cf spontaneous fission source was used. An excellent time resolution of 164ps has been observed at 6 mbar in isobutene gas. With the excellent time resolution of Dual-PPACs detector, exact neutron energy can be extracted from the timing measurement. The experimental detection efficiency was 1.9 × 10−7, consistent with the efficiency of 2.5 × 10−7 given by a Geant4 simulation. Ultimately, the results show that the Dual-PPACs detector is a suitable candidate for measuring fast neutrons in the future CiADS system.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次