期刊论文详细信息
Applied Sciences
A New Method to Determine the Steel Fibre Content of Existing Structures—Test Setup and Numerical Simulation
Simon Cleven1  Thomas Matschei1  Michael Raupach1 
[1] Institute of Building Materials Research, RWTH Aachen University, Schinkelstr. 3, 52062 Aachen, Germany;
关键词: steel fibre reinforced concrete;    electrical resistivity;    fibre content;    non-destructive test method;   
DOI  :  10.3390/app12020561
来源: DOAJ
【 摘 要 】

The diagnostics of constructions built with steel fibre reinforced concrete are extremely difficult to conduct because, typically, no information on the actual amount and orientation of the fibres is available. Therefore, it is of great interest to engineers to have the possibility to determine the steel fibre content and, at best, also the orientation of the fibres in existing structures. For this purpose, an easy-to-use test setup was developed and tested, in the course of laboratory investigations. This method can be used for cylinders, for example drilling cores, that can later be taken of existing structures, to determine both the fibre content and orientation. Based on these results, a model for cylindrical specimens was derived, which can be used for varying concrete compositions with steel fibre contents of up to 80 kg/m3. In the case of missing information concerning the concrete composition, it allows an initial estimation for the fibre content. In case additional information about the concrete composition is available, a much higher accuracy of the projected steel fibre content and therefore, an assessment of the building’s condition is possible.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次