Applied Sciences | |
Testing of a Dual-Steel-Plate-Confined High-Performance Concrete Composite Shaft Lining Structure and Its Application | |
Zhishu Yao1  Ping Zhang1  Xiang Li1  Weipei Xue1  Hua Cheng1  | |
[1] School of Civil Engineering and Architecture, Anhui University of Science and Technology, Huainan 232001, China; | |
关键词: high-performance concrete; dual-steel-plate-confined; composite shaft lining structure; test study; engineering application; | |
DOI : 10.3390/app10082938 | |
来源: DOAJ |
【 摘 要 】
Abstract: To address the support problem of large-diameter drilling shafts in the west area of Zhangji coal mine, a thinner shaft lining structure composed of double layers of steel plate and high-performance concrete is proposed herein. Firstly, a series of tests of high-performance concrete preparation were carried out, and the optimized mix ratio of pumping concrete with 60–70 MPa strength for shaft lining of the drilled shaft was obtained. Then, shaft lining models were designed according to the similarity theory, and the mechanical properties of the shaft lining were experimentally studied by loading test. The test results showed that the stress state of concrete in the shaft was obviously improved, and the compressive strength of concrete was increased by 1.97–2.52 times. Finally, the results of the study were applied to a shaft in the control strata of the inlet shaft in the west area of Zhangji coal mine, which made it possible to use the drilling method to construct the shaft. The following field measurement showed that the annular strain of the shaft lining concrete was −487 με, which is far less than the ultimate strain value of C65 concrete, and the shaft lining structure was kept safe and reliable.
【 授权许可】
Unknown