期刊论文详细信息
IET Cyber-Physical Systems
Data-driven control for combustion process of circulating fluidised bed boiler
Fang Fang1  Jizhen Liu1  Yajuan Liu1  Songyuan Yu1  Le Wei1 
[1] School of Control and Computer Engineering, North China Electric Power University;
关键词: combustion;    fossil fuels;    control system synthesis;    pulverised fuels;    three-term control;    boilers;    furnaces;    nonlinear control systems;    fluidised beds;    steam power stations;    learning systems;    coal;    active pid-parameter determination;    dd-pid control strategy;    bed boiler;    low-quality coal;    coal slime;    coal gangue;    deep load adjustment;    circulating fluidised bed combustion technology;    fossil fuel utilisation technologies;    pulverised coal boiler;    cfb boiler;    data-driven proportional–integral derivative control strategy;    combustion control;    generalised controlled object;    pid-parameter database establishment;    coupled variables;    time delay;    cfb simulation platform;    power 330.0 mw;   
DOI  :  10.1049/iet-cps.2019.0029
来源: DOAJ
【 摘 要 】

Owing to the advantages of burning low-quality coal (coal slime and coal gangue), furnace desulfurisation, low [inline-formula] emission and deep load adjustment, the circulating fluidised bed (CFB) combustion technology becomes one of the few fossil fuel utilisation technologies funded continuously by the Chinese government. However, compared with the pulverised coal boiler, the combustion process of CFB boiler is more complicated because of the larger time delay, significant uncertainty and more coupled variables. In this study, a data-driven proportional–integral-derivative (DD-PID) control strategy is presented for the combustion control of CFB boiler to improve the operating performance under full operating conditions. By analysing the running mechanism of combustion process, an inverse decoupler is introduced to transfer the combustion object to the generalised controlled object, which has relatively independent input–output relationship. After that, a normative procedure of DD-PID, including PID-parameter database establishment, information-vector neighbourhood selection, active PID-parameter determination, database update, and redundant vector deletion, is given. Finally, a series of case study, including numerical tests applied to the proposed combustion model and application test employed on 330 MW CFB simulation platform proves the feasibility of DD-PID control strategy.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:2次