期刊论文详细信息
Engineering Applications of Computational Fluid Mechanics 卷:12
Evaluation of in-pipe turbine performance for turbo solenoid valve system
M. Çakan1  Y. Mutlu1 
[1] Istanbul Technical University;
关键词: CFD;    flow control;    in-Pipe turbine;    process automation;    self-Sufficient system;    solenoid valve;   
DOI  :  10.1080/19942060.2018.1506364
来源: DOAJ
【 摘 要 】

This study is related to the newly developed and patented turbo solenoid turbine system. In this context, a numerical study was conducted on turbines with Darrieus, Gorlov and Lucid® configurations. As a result of the tests made on turbines with a NACA0018 aerofoil profile, the Lucid® turbine produced the highest moment and also highest pressure loss. Although a 10° twisted aerofoil Gorlov turbine produced 31.3% less moment than the Lucid® turbine, it also caused 51.4% less pressure loss. Also, it was observed that a Darrieus turbine with NACA0021 profile produced 1.5% less moment and 3.3% more pressure loss than a NACA0018 profile and turbine with NACA0015 profile, which produced 9% more moment and 1.4% more pressure loss than NACA0018. On the performance impact studies of the aerofoil twist angle, 20° twisted Gorlov turbines produced 19.1% more moment and 5.5% less pressure loss than a 10° twisted aerofoil turbine. Finally, a 20° twisted Gorlov turbine with NACA0015 aerofoil profile was analyzed. Following the studies, it was observed that the 20° twisted Gorlov turbine with NACA0015 aerofoil profile gave the best result by creating a 49.3% less pressure loss, in spite of only producing 4.7% less moment than the Lucid® turbine.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次