| Journal of International Council on Electrical Engineering | 卷:6 |
| Potential distribution on stress grading of inverter-fed rotating machines under DC biased voltage | |
| Steven A. Boggs1  Sakurai Takayuki2  Tetsuo Yoshimitsu2  Yuichi Tsuboi2  Tomohito Kisakibaru2  Takahiro Nakamura3  Akiko Kumada3  Hisatoshi Ikeda3  Kunihiko Hidaka3  | |
| [1] Institute of Materials Science, University of Connecticut; | |
| [2] Toshiba Mitsubishi-Electric Industrial Systems Corporation; | |
| [3] University of Tokyo; | |
| 关键词: rotating machine; voltage converter; stress grading system; form-wound coil; potential distribution; temperature distribution; | |
| DOI : 10.1080/22348972.2015.1115169 | |
| 来源: DOAJ | |
【 摘 要 】
The erosion of the stress grading system of converter-fed rotating machines may occur by partial discharges and heat generation. There remain unclear issues in the formation of the potential and temperature distributions along the stress grading system of coils. In this paper, the potential distributions on the stress grading system of the model coil bar are measured under the application of 1 kHz square wave voltages of 10 kV in peak to peak value with/without 5 kV DC biased voltage. It turns out that DC bias voltage has little effect on potential distribution on a coil surface.
【 授权许可】
Unknown