期刊论文详细信息
NeuroImage 卷:255
Resolution and b value dependent structural connectome in ex vivo mouse brain
Nian Wang1  Qi Zhao2  James C. Cook2  Yi Qi2  Gary Cofer2  Surendra Maharjan3  G. Allan Johnson4  Stephanie Crater4 
[1] Center for In Vivo Microscopy, Department of Radiology, Duke University, Durham, North Carolina, USA;
[2] Department of Radiology and Imaging Sciences, Indiana University, Indianapolis, Indiana, USA;
[3] Pratt School of Engineering, Duke University, Durham, North Carolina, USA;
关键词: HARDI;    Diffusion MRI;    Connectome;    Crossing fiber;    High-resolution;   
DOI  :  
来源: DOAJ
【 摘 要 】

Diffusion magnetic resonance imaging has been widely used in both clinical and preclinical studies to characterize tissue microstructure and structural connectivity. The diffusion MRI protocol for the Human Connectome Project (HCP) has been developed and optimized to obtain high-quality, high-resolution diffusion MRI (dMRI) datasets. However, such efforts have not been fully explored in preclinical studies, especially for rodents. In this study, high quality dMRI datasets of mouse brains were acquired at 9.4T system from two vendors. In particular, we acquired a high-spatial resolution dMRI dataset (25 μm isotropic with 126 diffusion encoding directions), which we believe to be the highest spatial resolution yet obtained; and a high-angular resolution dMRI dataset (50 μm isotropic with 384 diffusion encoding directions), which we believe to be the highest angular resolution compared to the dMRI datasets at the microscopic resolution. We systematically investigated the effects of three important parameters that affect the final outcome of the connectome: b value (1000s/mm2 to 8000 s/mm2), angular resolution (10 to 126), and spatial resolution (25 µm to 200 µm). The stability of tractography and connectome increase with the angular resolution, where more than 50 angles is necessary to achieve consistent results. The connectome and quantitative parameters derived from graph theory exhibit a linear relationship to the b value (R2 > 0.99); a single-shell acquisition with b value of 3000 s/mm2 shows comparable results to the multi-shell high angular resolution dataset. The dice coefficient decreases and both false positive rate and false negative rate gradually increase with coarser spatial resolution. Our study provides guidelines and foundations for exploration of tradeoffs among acquisition parameters for the structural connectome in ex vivo mouse brain.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次