期刊论文详细信息
European Medical Journal Cardiology 卷:4
RECURRENT CORONARY PERFORATIONS IN AN ANEURYSMAL CORONARY ARTERY TREATED WITH COVERED STENT
Udaya Prashant Ponangi1 
[1] Consultant Cardiologist in CARE Hospitals, Banjara Hills, Hyderabad, India;
关键词: thrombosuction;    total thrombotic occlusio;    hypertension;    stent;    post-dilatation;    coronary perforations;    aneurysmal coronary artery;    covered stent;   
DOI  :  
来源: DOAJ
【 摘 要 】

An elderly hypertensive lady presented to us with acute coronary syndrome; an angiogram revealed total thrombotic occlusion of large left circumflex artery. After thrombosuction, there was proximal tight stenosis followed by an aneurysmal segment of the culprit vessel that was stented successfully. Subsequent post-dilatation at the site of aneurysm produced a large perforation, which was sealed off immediately with a covered stent. Unfortunately, the patient had sudden cardiac tamponade and arrest later in the intensive cardiac care unit due to repeat perforation, and could not be resuscitated from this complication. Aneurysmal and ectatic arteries have fragile walls and aggressive post-dilatation for achieving optimal stent apposition should be avoided.

【 授权许可】

Unknown   

  文献评价指标  