期刊论文详细信息
Case Studies in Construction Materials 卷:16
Influence of recycled aggregates and carbon nanofibres on properties of ultra-high-performance concrete under elevated temperatures
Bassam A. Tayeh1  Ibrahim Saad Agwa2  Abdullah M. Zeyad3  Ahmed M. Maglad4  Mohamed Amin5  Ibrahim Y. Hakeem6 
[1] Civil Engineering Department, Faculty of Engineering, University of Science and Technology, Aden, Yemen;
[2] Corresponding author.;
[3] Civil Engineering Department, College of Engineering, Jazan University, Jazan, Saudi Arabia;
[4] Civil Engineering Department, Faculty of Engineering, Islamic University of Gaza, P.O. Box 108, Gaza Strip, Palestine;
[5] Civil and Architectural Constructions Department, Faculty of Technology and Education, Suez University, Egypt;
[6] Department of Civil Engineering, Najran University, Najran, Saudi Arabia;
关键词: Carbon nanofibers;    Hybrid fiber;    High temperature;    Natural coarse aggregate;    Recycled coarse aggregates;    UHPC;   
DOI  :  
来源: DOAJ
【 摘 要 】

Research interest in producing sustainable ultra high performance concrete (UHPC) has been increasing recently. This paper focuses on the use of recycled coarse aggregate (RCA) as a replacement for 50% of the total natural coarse aggregate (NCA). Two types of replacements were used, namely, carbon nanofiber (CNF) with 0.25%, 0.5%, 0.75%, and 1% by weight of binder and steel fibers (SFs) with 0.5%, 1.0%, 1.5% and 2% of by weight of the binder. In addition to this, hybrid fibers, i.e. a combination of CNF with SFs were also used for few mixes. Twenty-six mixtures were prepared to evaluate the engineering properties of UHPCs containing RCA and NCA with CNF and SFs. The mechanical properties were evaluated through tests of the compressive, split tensile, and flexural strengths and the modulus of elasticity. The mass and compressive strength losses were examined to evaluate the effect of UHPC exposure to elevated temperatures (200 °C, 400 °C, 600 °C, and 800 °C). The incorporation of NCF, SFs, and RCA negatively affected the workability, and the diameter of the slump flow was reduced to 230 mm for RCF0. 25-SF2.0 mixture. The addition of fiber contributed to the improvement of the concrete properties. The compressive strengths were 151.3 and 146.9 MPa for the NF0 and RF0 mixtures, respectively. In fiber addition to UHPC, the best improvement was achieved at 164.9, 158.6, 158.8, 153.5, 167.9 and 180.9 MPa for the NCF0.5, RCF0.5, NSF2.0, RSF2.0, NCF0.25-SF2.0 and RCF0. 25-SF2.0 mixtures.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:3次