期刊论文详细信息
Journal of Synchrotron Radiation 卷:29
X-ray absorption spectroscopy and actinide electrochemistry: a setup dedicated to radioactive samples applied to neptunium chemistry
Dominique Guillaumont1  Philippe Moisy1  Richard Husar1  Thomas Dumas1  Michel L. Schlegel2  Daniel Schlegel3  Pier-Lorenzo Solari4 
[1] CEA, DES, ISEC, DMRC, Université de Montpellier, Marcoule, France;
[2] CEA, DES-Service d'Etudes Analytiques et de Réactivité des Surfaces (SEARS), CEA, Université Paris-Sacly, 911191 Gif-sur-Yvette, France;
[3] ESTA–École Supérieure des Technologies et des Affaires, 90004 Belfort Cedex, France;
[4] Synchrotron SOLEIL, L'Orme des Merisiers Saint-Aubin, BP 48, 91192 Gif-sur-Yvette Cedex, France;
关键词: x-ray absorption spectroscopy;    xas;    actinide;    electrochemistry;    radioactive sample;    neptunium chemistry;   
DOI  :  10.1107/S1600577521011115
来源: DOAJ
【 摘 要 】

A spectroelectrochemical setup has been developed to investigate radioactive elements in small volumes (0.7 to 2 ml) under oxidation–reduction (redox) controlled conditions by X-ray absorption spectroscopy (XAS). The cell design is presented together with in situ XAS measurements performed during neptunium redox reactions. Cycling experiments on the NpO22+/NpO2+ redox couple were applied to qualify the cell electrodynamics using XANES measurements and its ability to probe modifications in the neptunyl hydration shell in a 1 mol l−1 HNO3 solution. The XAS results are in agreement with previous structural studies and the NpO22+/NpO2+ standard potential, determined using Nernst methods, is consistent with measurements based on other techniques. Subsequently, the NpO2+, NpO22+ and Np4+ ion structures in solution were stabilized and measured using EXAFS. The resulting fit parameters are again compared with other results from the literature and with theoretical models in order to evaluate how this spectroelectrochemistry experiment succeeds or fails to stabilize the oxidation states of actinides. The experiment succeeded in: (i) implementing a robust and safe XAS device to investigate unstable radioactive species, (ii) evaluate in a reproducible manner the NpO22+/NpO2+ standard potential under dilute conditions and (iii) clarify mechanistic aspects of the actinyl hydration sphere in solution. In contrast, a detailed comparison of EXAFS fit parameters shows that this method is less appropriate than the majority of the previously reported chemical methods for the stabilization of the Np4+ ion.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次