期刊论文详细信息
Sensors 卷:12
An Improved Force Feedback Control Algorithm for Active Tendons
关键词: vibration control;    active tendon;    differential force feedback;   
DOI  :  10.3390/s120811360
来源: DOAJ
【 摘 要 】

An active tendon, consisting of a displacement actuator and a co-located force sensor, has been adopted by many studies to suppress the vibration of large space flexible structures. The damping, provided by the force feedback control algorithm in these studies, is small and can increase, especially for tendons with low axial stiffness. This study introduces an improved force feedback algorithm, which is based on the idea of velocity feedback. The algorithm provides a large damping ratio for space flexible structures and does not require a structure model. The effectiveness of the algorithm is demonstrated on a structure similar to JPL-MPI. The results show that large damping can be achieved for the vibration control of large space structures.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次