期刊论文详细信息
Journal of Dental Medicine 卷:29
Efficacy of calibration function by CMOS digital system software for working length estimation
Alieh Sadat JavadzadehHaghighat1  Mohtavipour Seyedeh Tahereh1  Seyedeh SaeidehMohtavipour2  ShivaSadeghi3  Bahar MahmoudKhalesi4  MaryamRezvani4 
[1] Assistant Professor, Department of Oral and Maxillofacial Radiology, School of Dentistry, Guilan University of Medical Sciences, Guilan, Iran;
[2] Assistant Professor, Department of Pediatricdentistry, School of Dentistry, Guilan University of Medical Sciences, Guilan, Iran;
[3] Associate Professor, Department of Endodotics, School of Dentistry, Guilan University of Medical Sciences, Guilan, Iran;
[4] Dentist;
关键词: Digital radiography;    Measurement;    Root canal;   
DOI  :  
来源: DOAJ
【 摘 要 】

Background and Aims: Estimating the canal length is essential for reaching to a proper endodontic treatment. Any error and miscalculation in estimation of the working length, especially in curved canals, can result in complication during and after root canal therapy. The introduction of digital radiography has enabled us to measure curved canal length. The purpose of this study was to evaluate the calibration tool of Complementary Metal Oxide Semiconductor (CMOS) digital system in estimation of working length.Materials and Methods: In this in-vitro study, 80 extracted molar teeth were selected and randomly divided into three groups based on angle and radius of canal curvature. A 5 mm orthodontic wire was placed on the lateral surface of the root. Conventional radiographs were taken after insertion of endodontic file in the apical third of root canals. Radiographic images were scanned and imported to the software of CMOS digital system. Two observers estimated the file lengths with and without using calibration tool of digital measurement software. The correlation between observers was evaluated and then data were analyzed using Paired T-test with 95% confidence.Results: Overall agreement between observers was good. There was no significant difference between the mean values of calibrated measurement and true file length in the basis of canal curves (P>0.001). However, there was significant difference between the mean values of uncalibrated measurement and true file length in the basis of canal curvature (P<0.001).Conclusion: The calibrated measurement of file length was more accurate than that of the uncalibrated file length measurement.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次