Perioperative non-invasive versus semi-invasive cardiac index monitoring in patients with bariatric surgery – a prospective observational study
Phil Klose1  Matthias Gruenewald1  Gunnar Elke1  Jonathan Hansen1  Markus Pohlmann1  Ulf Lorenzen1  Jochen Renner2 
[1] Department of Anaesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel;
[2] Department of Anesthesiology, Helios Kliniken Schwerin;
关键词: Bariatric surgery;    Cardiac output;    Finger-cuff;    Hemodynamic monitoring;    Non-invasive monitoring;    Obesity;   
DOI  :  10.1186/s12871-020-01110-x
来源: DOAJ
【 摘 要 】

Abstract Background In morbidly obese patients undergoing laparoscopic bariatric surgery, the combination of obesity-related comorbidities, pneumoperitoneum and extreme posture changes constitutes a high risk of perioperative hemodynamic complications. Thus, an advanced hemodynamic monitoring including continuous cardiac index (CI) assessment is desirable. While invasive catheterization may bear technical difficulties, transesophageal echocardiography is contraindicated due to the surgical procedure. Evidence on the clinical reliability of alternative semi- or non-invasive cardiac monitoring devices is limited. The aim was to compare the non-invasive vascular unloading to a semi-invasive pulse contour analysis reference technique for continuous CI measurements in bariatric surgical patients. Methods This prospective observational study included adult patients scheduled for elective, laparoscopic bariatric surgery after obtained institutional ethics approval and written informed consent. CI measurements were performed using the vascular unloading technique (Nexfin®) and semi-invasive reference method (FloTrac™). At 10 defined measurement time points, the influence of clinically indicated body posture changes, passive leg raising, fluid bolus administration and pneumoperitoneum was evaluated pre- and intraoperatively. Correlation, Bland-Altman and concordance analyses were performed. Results Sixty patients (mean BMI 49.2 kg/m2) were enrolled into the study and data from 54 patients could be entered in the final analysis. Baseline CI was 3.2 ± 0.9 and 3.3 ± 0.8 l/min/m2, respectively. Pooled absolute CI values showed a positive correlation (rs = 0.76, P < 0.001) and mean bias of of − 0.16 l/min/m2 (limits of agreement: − 1.48 to 1.15 l/min/m2) between the two methods. Pooled percentage error was 56.51%, missing the criteria of interchangeability (< 30%). Preoperatively, bias ranged from − 0.33 to 0.08 l/min/m2 with wide limits of agreement. Correlation of CI was best (rs = 0.82, P < 0.001) and percentage error lowest (46.34%) during anesthesia and after fluid bolus administration. Intraoperatively, bias ranged from − 0.34 to − 0.03 l/min/m2 with wide limits of agreement. CI measurements correlated best during pneumoperitoneum and after fluid bolus administration (rs = 0.77, P < 0.001; percentage error 35.95%). Trending ability for all 10 measurement points showed a concordance rate of 85.12%, not reaching the predefined Critchley criterion (> 92%). Conclusion Non-invasive as compared to semi-invasive CI measurements did not reach criteria of interchangeability for monitoring absolute and trending values of CI in morbidly obese patients undergoing bariatric surgery. Trial registration The study was registered retrospectively on June 12, 2017 with the registration number NCT03184272 .

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次