期刊论文详细信息
Case Studies in Thermal Engineering 卷:26
Integrated closed cooling system for high-power chips
Tao Wei1  Jiyu Qian2  Haojie Huang3  Rui Wang3 
[1] Nanjing Research Institute of Electronics Technology, Jiangsu, Nanjing, 210039, China;
[2] Corresponding author.;
关键词: Cooling architecture;    High-power chips;    Micro-channel;    Heat dissipation;   
DOI  :  
来源: DOAJ
【 摘 要 】

With the innovation of high power and high integration for chips in microwave devices, the research of high-efficiency integrated cooling system is advancing. Current cooling architecture has disadvantages of poor impurity tolerance, large terminal heat exchanger, and low system reliability. An integrated closed cooling system is proposed to conquer cooling problems in radio frequency microsystem. A principle prototype of the closed cooling system is established, integrated with micropump, heat exchanger, and silicon based micro-channel substrate. A heat flux of 500 W/cm2 for high-power chip cooling is achieved with temperature rise less than 50 °C, which demonstrates high efficiency and reliability of present integrated closed cooling system.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次