BMC Medical Imaging
Clinical value of resting cardiac dual-energy CT in patients suspected of coronary artery disease
Fangfang Yu1  Mingxi Liu1  Wenhuan Li1  Chengxi Yan2 
[1] Department of Radiology, Beijing Chao-Yang Hospital, Capital Medical University, 8 Gongren Tiyuchang Nanlu, Chaoyang District, 100020, Beijing, China;Department of Radiology, Xuanwu Hospital of Capital Medical University, No. 45, Chang-Chun Street, Xicheng District, 100053, Beijing, China;
关键词: Dual-energy CT;    Myocardial perfusion;    Coronary artery disease;    Invasive coronary angiography;    Positron emission tomography;   
DOI  :  10.1186/s12880-022-00761-1
来源: Springer
PDF
【 摘 要 】

BackgroundRest/stress myocardial CT perfusion (CTP) has high diagnostic value for coronary artery disease (CAD), but the additional value of resting CTP especially dual-energy CTP (DE-CTP) beyond coronary CT angiography (CCTA) in chest pain triage remains unclear. We aimed to evaluate the diagnostic accuracy of resting myocardial DE-CTP, and additional value in detecting CAD beyond CCTA (obstructive stenosis: ≥ 50%) in patients suspected of CAD.MethodsIn this prespecified subanalysis of 54 patients, we included patients suspected of CAD referred to invasive coronary angiography (ICA). Diagnostic accuracy of resting myocardial DE-CTP in detecting myocardial perfusion defects was assessed using resting 13N-ammonia positron emission tomography (PET) as the gold standard. Diagnostic accuracy of cardiac dual-energy CT in detecting flow-limiting stenoses (justifying revascularization) by CCTA combined with resting myocardial DE-CTP, using ICA plus resting 13N-ammonia PET as the gold standard. The CCTA and DE-CTP datasets derived from a single-phase scan performed with dual-energy mode.ResultsFor detecting myocardial perfusion defects, DE-CTP demonstrated high diagnostic accuracy with a sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) of 95.52%, 85.93%, and 0.907 on a per-segment basis. For detecting flow-limiting stenoses by CCTA alone, sensitivity, specificity, and AUC were 100%, 56.47%, and 0.777 respectively on a per-vessel basis. For detecting flow-limiting stenoses by CCTA combined with resting myocardial DE-CTP, sensitivity, specificity, and AUC were 96.10%, 95.29% and 0.956 respectively on a per-vessel basis. Additionally, CCTA combined with resting myocardial DE-CTP detected five patients (9%) with no obstructive stenosis but with myocardial perfusion defects confirmed by ICA plus 13N-ammonia PET.ConclusionsResting cardiac DE-CTP demonstrates a high diagnostic accuracy in detecting myocardial perfusion defects and provides an additional clinical value by reducing rates of false-positive and false-negative patients beyond CCTA in patients suspected of CAD.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202202189024482ZK.pdf 1275KB PDF download
  文献评价指标  
  下载次数:11次 浏览次数:5次