期刊论文详细信息
BMC Ophthalmology
Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORA
Bachar Kudsieh1  Ricardo P. Casaroli-Marano2  María Iglesias3  Jeroni Nadal3  Andrea Laiseca3  Rafael Barraquer4  Cristina Santos5 
[1] Department of Ophthalmology, Hospital Universitario Puerta De Hierro, 28222, Madrid, Spain;Department of Surgery, School of Medicine and Hospital Clinic de Barcelona, University of Barcelona (UB), 08036, Barcelona, Spain;Instituto Universitario Barraquer, Barraquer Ophthalmology Centre, Laforja 88, 08012, Barcelona, Spain;Instituto Universitario Barraquer, Barraquer Ophthalmology Centre, Laforja 88, 08012, Barcelona, Spain;International University of Catalunya (UIC), 08017, Barcelona, Spain;Unitat Antropologia Biològica, Department Biologia Animal, Biologia Vegetal i Ecologia, Universitat Autònoma de Barcelona (UAB), 08193, Barcelona, Spain;
关键词: Tonometry;    Corneal biomechanics;    Intraocular pressure;    Glaucoma;    Myopia;    LASIK;    PRK;   
DOI  :  10.1186/s12886-022-02309-x
来源: Springer
PDF
【 摘 要 】

BackgroundThe purpose of this study is to describe measurements using a newly developed modified Goldmann convex tonometer (CT) 1 year after myopic laser refractive surgery. Intraocular pressure (IOP) measurements were compared with IOP values obtained by Goldmann applanation tonometer (GAT), and Ocular Response Analyzer (ORA).MethodsProspective double-masked study performed on thirty eyes of thirty patients that underwent laser in situ keratomileusis (LASIK; n = 19) or photorefractive keratectomy (PRK; n = 11). IOP was measured before and 3 and 12 months after surgery. Intraclass correlation coefficient (ICC) and Bland-Altman plot were calculated to assess the agreement between GAT, CT, IOPg (Goldmann-correlated IOP) and IOPcc (corneal-compensated IOP) from ORA.ResultsTwelve months after LASIK, IOP measured with CT showed the best correlation with IOP measured with GAT before surgery (GATpre) (ICC = 0.886, 95% CI: 0.703–0.956) (15.60 ± 3.27 vs 15.80 ± 3.22; p < 0.000). However, a moderate correlation was found for IOP measured with IOPcc and CT 12 months after LASIK (ICC = 0.568, 95% CI: − 0.185 – 0.843) (15.80 ± 3.22 vs 12.87 ± 2.77; p < 0.004). Twelve months after PRK, CT showed a weak correlation (ICC = − 0.266, 95% CI: − 3.896 – 0.663), compared to GATpre (17.30 ± 3.47 vs 16.01 ± 1.45; p < 0.642), as well as poor correlation (ICC = 0.256, 95% CI: − 0.332 – 0.719) with IOPcc (17.30 ± 3.47 vs 13.38 ± 1.65; p < 0.182).ConclusionsTwelve months after LASIK, IOP measured with CT strongly correlated with GAT before surgery and could therefore provide an alternative method for measuring IOP after this surgery. More studies regarding this new convex prism are needed to assess its accuracy.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202202187199608ZK.pdf 1060KB PDF download
  文献评价指标  