期刊论文详细信息
Journal of Cardiovascular Magnetic Resonance
Accuracy of stroke volume measurement with phase-contrast cardiovascular magnetic resonance in patients with aortic stenosis
Eric Larose1  Philippe Pibarot1  Mylène Shen1  Marie-Annick Clavel1  Lionel Tastet1  Ezequiel Guzzetti1  Hugo-Pierre Racine1  Jonathan Beaudoin1 
[1] Institut Universitaire de Cardiologie et de Pneumologie de Québec, Université Laval, 2725 Chemin Sainte-Foy, G1V-4G5, Québec, QC, Canada;
关键词: Phase contrast;    Aortic stenosis;    Valvular heart disease;   
DOI  :  10.1186/s12968-021-00814-4
来源: Springer
PDF
【 摘 要 】

BackgroundPhase contrast (PC) cardiovascular magnetic resonance (CMR) in the ascending aorta (AAo) is widely used to calculate left ventricular (LV) stroke volume (SV). The accuracy of PC CMR may be altered by turbulent flow. Measurement of SV at another site is suggested in the presence of aortic stenosis, but very few data validates the accuracy or inaccuracy of PC in that setting. Our objective is to compare flow measurements obtained in the AAo and LV outflow tract (LVOT) in patients with aortic stenosis.MethodsRetrospective analysis of patients with aortic stenosis who had CMR and echocardiography. Patients with mitral regurgitation were excluded. PC in the AAo and LVOT were acquired to derive SV. LV SV from end-systolic and end-diastolic tracings was used as the reference measure. A difference ≥ 10% between the volumetric method and PC derived SVs was considered discordant. Metrics of turbulence and jet eccentricity were assessed to explore the predictors of discordant measurements.ResultsWe included 88 patients, 41% with bicuspid aortic valve. LVOT SV was concordant with the volumetric method in 79 (90%) patients vs 52 (59%) patients for AAo SV (p = 0.015). In multivariate analysis, aortic stenosis flow jet angle was a strong predictor of discordant measurement in the AAo (p = 0.003). Mathematical correction for the jet angle improved the concordance from 59 to 91%. Concordance was comparable in patients with bicuspid and trileaflet valves (57% and 62% concordance respectively; p = 0.11). Accuracy of SV measured in the LVOT was not influenced by jet eccentricity. For aortic regurgitation quantification, PC in the AAo had better correlation to volumetric assessments than LVOT PC.ConclusionLVOT PC SV in patients with aortic stenosis and eccentric jet might be more accurate compared to the AAo SV. Mathematical correction for the jet angle in the AAo might be another alternative to improve accuracy.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202112047398277ZK.pdf 1629KB PDF download
  文献评价指标  
  下载次数:0次 浏览次数:3次