期刊论文详细信息
BMC Cardiovascular Disorders
Extracellular volume quantification using synthetic haematocrit assessed from native and post-contrast longitudinal relaxation T1 times of a blood pool
Lenka Spinarova1  Lucia Masarova2  Lukas Opatril2  Vladimir Kincl2  Roman Panovsky3  Marek Hodejovsky4  Tomas Holecek5  Vera Feitova5  Jan Machal6 
[1] 1st Department of Internal Medicine and Cardioangiology, St. Anne’s University Hospital, Brno, Czech Republic;Faculty of Medicine, Masaryk University, Brno, Czech Republic;1st Department of Internal Medicine and Cardioangiology, St. Anne’s University Hospital, Brno, Czech Republic;International Clinical Research Center, St. Anne’s University Hospital, Brno, Czech Republic;Faculty of Medicine, Masaryk University, Brno, Czech Republic;1st Department of Internal Medicine and Cardioangiology, St. Anne’s University Hospital, Brno, Czech Republic;International Clinical Research Center, St. Anne’s University Hospital, Brno, Czech Republic;Faculty of Medicine, Masaryk University, Brno, Czech Republic;1st Department of Internal Medicine and Cardioangiology, International Clinical Research Center, St. Anne’s University Hospital, Brno, Czech Republic;Faculty of Medicine, Masaryk University, Brno, Czech Republic;International Clinical Research Center, St. Anne’s University Hospital, Brno, Czech Republic;Department of Medical Imaging, St. Anne’s University Hospital, Brno, Czech Republic;International Clinical Research Center, St. Anne’s University Hospital, Brno, Czech Republic;Department of Pathophysiology, Faculty of Medicine, Masaryk University, Brno, Czech Republic;
关键词: Extracellular volume;    ECV;    Synthetic haematocrit;    Cardiovascular magnetic resonance;    CMR;   
DOI  :  10.1186/s12872-021-02179-z
来源: Springer
PDF
【 摘 要 】

BackgroundIn terms of cardiovascular magnetic resonance are haematocrit values required for calculation of extracellular volume fraction (ECV). Previously published studies have hypothesized that haematocrit could be calculated from T1 blood pool relaxation time, however only native T1 relaxation time values have been used and the resulting formulae had been both in reciprocal and linear proportion. The aim of the study was to generate a synthetic haematocrit formula from only native relaxation time values first, calculate whether linear or reciprocal model is more precise in haematocrit estimation and then determine whether adding post-contrast values further improve its precision.MethodsOne hundred thirty-nine subjects underwent CMR examination. Haematocrit was measured using standard laboratory methods. Afterwards T1 relaxation times before and after the application of a contrast agent were measured and a statistical relationship between these values was calculated.ResultsDifferent linear and reciprocal models were created to estimate the value of synthetic haematocrit and ECV. The highest coefficient of determination was observed in the combined reciprocal model “− 0.047 + (779/ blood native) − (11.36/ blood post-contrast)”.ConclusionsThis study provides more evidence that assessing synthetic haematocrit and synthetic ECV is feasible and statistically most accurate model to use is reciprocal. Adding post-contrast values to the calculation was proved to improve the precision of the formula statistically significantly.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202109177868675ZK.pdf 1240KB PDF download
  文献评价指标  
  下载次数:1次 浏览次数:2次